Putting data centers on decommissioned ships and reusing hot water from cooling systems to fill the town swimming pool were among the wackier ideas floated at the Data Center Energy Summit last week.
Data center operators came together to compare notes about the best ways to tackle rising energy consumption at their facilities. Ideas ranged from the exotic to the more down to earth, like improving air-flow management and using outside air in colder climates to cool equipment.
After a brief lull a few years ago, a new wave of data center construction and expansion is under way, stretching the power and cooling capacities of existing facilities and putting pressure on utilities' electrical grids, speakers said.
Subodh Bapat, vice president for energy efficiency at Sun Microsystems, described a perfect storm of factors that are forcing data centers to become more power efficient.
The electricity consumed by microprocessors is increasing by 16 per cent per year as they become more powerful, he said, which contributes to a 14 per cent increase in the power consumed by each new generation of servers. At the same time, energy prices in the US have increased by about 12 per cent on average for the past three years and are expected to keep climbing.
That's forcing some data centers to consider unusual solutions. One large health-care center is looking at reusing hot water expelled by its cooling systems to do its laundry, Bapat said. A hosting company in the Northeast is freezing water overnight, when the cost of electricity is cheaper, and then blowing air over the ice during the day to provide cold air for cooling systems.
Another company hopes to put portable data centers on ships docked at port, giving it "the biggest heat sync in the world [the ocean] to get rid of waste heat," Bapat said.
Most people at the summit here were looking for more down-to-earth solutions. They were offered by several large data centers who discussed results from pilot tests designed to help show the real-world savings offered by from various energy-saving techniques.
One of the most effective is better air-flow management, so that cold air pumped in to cool equipment doesn't mix with hot exhaust air coming out, said Bill Tschudi of the Lawrence Berkeley National Laboratory.
Many data centers use alternating hot and cold aisles to keep warm and cold air separate, but that method is only partially effective because the air mixes in the spaces above the aisles, Tschudi said.
Oracle tested "hot-aisle containment" at a data center in Austin, Texas, which involves building an enclosure around server racks so that the hot exhaust can be siphoned off. Cooling systems account for as much as half the energy consumed by some data centers, said Mukesh Khattar, who heads Oracle's energy efforts.
Discover how SOA can create smarter outcomes for your business.
Attend and learn:
- How SOA is helping leading companies to become more agile
- Where you should be applying SOA processes in your company
- The top SOA implementation mistakes to avoid
Click here for more information.
- +
Computerworld Live Podcast #97: The Future of Enterprise Networking 25/07/2008 09:45:36
This week CW Live chats with Mark Thompson, global sales and marketing manager for HP ProCurve, on the future of the enterprise networking. Mark discusses the trends we can expect to see in the near future and how the right infrastructure can ensure your enterprise network is secure. - +
Computerworld Live Podcast #96: Security at the Edge 11/06/2008 09:22:22
CW Live speaks with Amol Mitra, HP ProCurve Director of Marketing for Asia Pacific and Japan. Today's topic: how enterprises are starting to shift away from simply controlling security via server logins, firewalls and moving to more adaptive security frameworks. - +
Data Management Edition #10: Multi-Petascale Systems 02/05/2008 09:12:33
This week we look at sustainability and the development of multicore technologies to build multi-petascale systems. - +
IT Security Edition #11: How to poison the Storm botnet 01/05/2008 08:51:55
This week CW Live presents a case study on how to poison the notorious Storm botnet . Plus we take a look at Cisco's plans for Ironport. - +
IT Security Edition #10: Cyber-battles fought and won 24/04/2008 11:09:47
Vendors bow to end user pressure to improve product security, and we take a look at the latest concepts shaping the cyber-battlefield of the future.
FrontRange Solutions launches HEAT Plus Mobile to reduce help desk costs and improve service management productivity 2008-12-02 15:15:00+11
AARNet Helps to Advance Indigenous Health 2008-12-02 12:44:00+11
Orbis selects Telstra International as its data centre partner for the UK, Europe and Middle East Region 2008-12-02 11:23:00+11
ComOps Deploys Corporate Performance Reporting Solution For Healthcare Test Manufacturer 2008-12-02 10:09:00+11
Mornington Peninsula Shire implements Objective to manage knowledge and deliver service excellence 2008-12-02 09:56:00+11
Mimosa™ NearPoint™ for Microsoft® Exchange Server: Email Archiving 101
Email archiving is emerging as a critical new application for managing email. Learn how to reduce and manage online and offline email storage, add powerful tools for legal discovery and compliance and extend native exchange recovery capability by reading on.